Example of installation of conventional illuminated signs
The problem with the conventional internally-illuminated signs is that they are difficult to maintain because lane regulations are required during maintenance of lighting equipment.
[New technology] New external light marking system
Illuminate the signboard surface using the lighting installed on the shoulder wall surface, and attach a prism type reflection sheet that diffuses to the signboard surface to make the sign look bright
By installing the light fixture on the shoulder wall surface, it is possible to perform maintenance without lane regulation.
By installing the light fixture on the shoulder wall surface, it is possible to perform maintenance without lane regulation.
Diffusing prism type reflection sheet
Image of installation of new external lighting sign system
Status of test construction