Traffic management/facility equipment
Compact IP transmission device (NET-SP1)
NEXCO Engineering Tohoku Co., Ltd.
Product Summary
NET-SP1 is a device that inputs contact inputs, analog values, and pulse signals and performs IP conversion transmission.
Cascade connection makes it possible to handle more than the maximum number of units that can be monitored and controlled, and also supports multiple input voltages. It is a compact and lightweight device with excellent cost performance that can be hung on a wall without being restricted by the installation location.
Each piece of equipment information is sent to the central unit via the IP network. The control signal from the central unit is sent to each facility through the compact IP transmission unit.
- Light section IG (intelligent)
Successor to the slave station
Realizing a general-purpose transmission device against the backdrop of recent improvements in computer processing capabilities.
- Scalability
Further network configuration is possible through the IP network. The network configuration of "web image", "maintenance terminal", "IP transmission device monitoring network", and "other information" is possible from the LAN connection port provided on the CPU board.
Features/Specifications
Can be constructed by freely combining control/monitor unit boards for each voltage
Monitor at maximum 96 Point, control 48 Can handle points
External dimensions |
W500mm, H450mm, D280mm |
weight |
Maximum weight 25.2kg |
Operating temperature |
0〜40℃ |
Operating humidity |
20-80% non-condensing |
cooling method |
Natural air cooling |
Installation location |
Indoor installation |
Input voltage |
AC100V DC100V DC48V |
Power consumption |
150W |
Transmission procedure |
TCP/IP |
LAN |
10BASE-T |
Number of units |
13 units (including PS board and CPU board) |
Corresponding voltage |
DC24V DC48V DC110V |
- Adopts a board corresponding to the input voltage
Correspondence of different input voltage is supported inside the board. Therefore, it is possible to mount different voltage boards on each slit.
- Substrate in consideration of maintainability
Each mounting board is not limited to the monitored location, but can be commonly used at other monitored locations.
In the event of a failure, you can basically replace the board and replace it with the "send back method."
NET-SP1: Network & NEXCO Engineering Tohoku — Small Package Type 1
*This product is limited to Tohoku Regional Head Office.
Achievements (sales/construction/introduction)